How Much Does It Cost to Run an Air Conditioner?
The running cost of air conditioning frightens people out of proportion — or lulls them, depending on which neighbour they ask. The truth is a short multiplication away: a unit's electrical input, the hours it runs, and your electricity rate. Everything else is refinement.
This guide shows the calculation for window units, splits and central systems, explains the efficiency ratings on the label, and covers the settings that move the answer most.
An air conditioner is a machine that moves heat, and its cost is the cost of running that machine for the hours you need it. The calculation is a short one: the electrical power the unit draws, multiplied by the hours it runs, multiplied by your rate. The difficulty is not the arithmetic but the inputs, because the power a unit draws and the hours it runs are both easy to get wrong, and each of them moves the answer in proportion. This guide works through both, and it finishes with a scenario you can check against your own unit.
The same three numbers appear in the Air Conditioner Cost Calculator on this site: the input power in kilowatts, the hours per day, and the number of days. The duty cycle is the fourth input, and it is the one most people leave at 100 percent even when their unit cycles. Get those four numbers right, and the calculator gives you a cost you can plan around; get one of them wrong, and it gives you a cost for a different air conditioner in a different house.
The calculators linked at the end of this guide are the tools for the method in this guide: Air Conditioner Cost Calculator, Electricity Cost Calculator. Use them first with the numbers from the worked scenario above, and then again with your own numbers, and keep both answers. The first run checks that you have understood the method, because it should reproduce the scenario; the second run gives you the answer for your own home, and it is the one to act on. If the two runs disagree by more than you expect, the difference is in an input, and the field help text on the calculator will tell you which one to check first.
Step 1: find the electrical input in kW
Cooling capacity (in BTU per hour) is not power consumption. Divide it by the unit's EER to get watts: a 12,000 BTU/h unit at EER 12 draws 12,000 ÷ 12 = 1,000 W, or 1 kW. If the label gives electrical input directly in kW, use that and skip the division.
SEER (and its newer US successor SEER2) is a seasonal average efficiency rather than a single-condition rating; EER is the cleaner input for an hourly cost estimate. When only SEER is published, using it in the same formula gives a reasonable seasonal approximation.
Step 2: honest hours, and the duty cycle
A thermostat-controlled unit does not draw full power every minute it is "on": the compressor cycles. On a mild day the effective draw might be half the rated input; in a heatwave, nearly all of it. Our AC Calculator carries a duty-cycle input for exactly this — leave it at 100% for a worst-case day, reduce it for seasonal estimates.
Step 3: multiply by your rate — an example
The 1 kW unit above, running 8 hours a day for 30 days at full duty, uses 240 kWh. At the US average residential price of $0.1819/kWh that is $43.66 for the month; at the UK price cap of £0.2632/kWh, £63.17. The same comfort, two very different bills — which is why every Dwellario answer starts from your rate, not a generic one.
What moves the answer most
- Thermostat setting: each degree lower lengthens compressor runtime; experiment upward until comfort, not habit, decides.
- Solar gain: sun through unshaded glass is heat the unit must remove — external shading and blinds work before the compressor does.
- Maintenance: clogged filters and coils degrade both capacity and efficiency.
- Sizing: a chronically oversized unit short-cycles (poor humidity control, wear); undersized runs continuously on hot days. Both show up in the duty cycle.
Estimating a whole season
Multiply a typical day by the number of cooling days, but weight it: a handful of extreme days can consume like weeks of mild ones. If your utility provides daily usage data, last summer's hottest month is a better template than an average month.
A worked scenario, step by step
Take a unit whose input power is 1.5 kW, which is a scenario assumption for this worked example: check your own unit on its specification plate and use that number instead. Suppose it runs 5 hours a day for 30 days, which is a month, at full duty, and that the rate is 0.1819 per kWh. The energy is 1.5 times 5 times 30, which is 225 kWh in the month, and the cost is 225 times 0.1819, which is 40.93.
Now apply the duty cycle, because most units do not draw full power for the whole time they are on. At a 60 percent duty cycle, which is inside the 60 to 80 percent range the calculator help text gives for units that have cooled the room, the effective energy is 225 times 0.60, which is 135 kWh, and the cost is 135 times 0.1819, which is 24.56. The difference between the two answers, 40.93 minus 24.56, is 16.37, and it comes entirely from the duty cycle: the same unit, the same hours, the same rate, and a different answer because the compressor cycles.
For a whole cooling season of about 90 days, multiply the monthly figures by three. At full duty the season is 225 times 3, which is 675 kWh, costing 122.78 at 0.1819 per kWh; at 60 percent duty it is 135 times 3, which is 405 kWh, costing 73.67. The season is where the duty cycle matters most, because a small difference in the daily figure is multiplied by ninety days. Run the calculator with your own input power, hours, days and duty cycle, and compare the monthly figure with a real bill before you trust the seasonal one.
Common traps
Air conditioning costs are usually overestimated or underestimated for the same few reasons:
- Using the cooling capacity, in BTU per hour, as if it were the electrical input power. The cooling capacity is the heat the unit moves; the input power is the electricity it draws to move it, and it is much smaller. The calculator asks for the input power, or it derives it from the capacity and the efficiency rating.
- Leaving the duty cycle at 100 percent for a unit that cycles. A unit that has cooled the room switches its compressor off and on, and the calculator help text puts that at 60 to 80 percent for many units. One hundred percent is the safe upper estimate, not the typical one.
- Mixing up EER and SEER. EER is measured at full load, and SEER is a seasonal average, so the two give different input powers for the same unit. Use the rating your unit actually carries, and read the assumptions section of the calculator for the difference.
- Counting the days wrong. A month is 30 days in the calculator, and a full cooling season is about 90 days: using 30 days where you meant a season understates the answer by a factor of three.
Decision checklist
Before you buy, or before you budget for a season, work through this list:
- Read the input power, in kilowatts, from the unit specification plate, or work it out from the cooling capacity and the efficiency rating.
- Decide the hours per day honestly, from how you actually use the unit, not from how you hope to use it.
- Set the duty cycle to 100 percent for an upper estimate, then re-run it at 60 to 80 percent for a typical one, and keep both answers.
- Multiply the monthly answer by three for a season of about 90 days, and compare the monthly answer with a real bill.
- If the two answers are far apart, check the rate and the days before you doubt the unit.
A second unit, and a second season
Most homes that have one air conditioner have more than one, or they add a second one, and the cost of the second unit is the cost of the first multiplied by the number of units, provided the units are the same size and run the same hours. Take the scenario above at 60 percent duty: one unit used 135 kWh in a month, costing 24.56. Two such units use 135 times 2, which is 270 kWh in a month, costing 270 times 0.1819, which is 49.11. Over a season of about 90 days, two units use 405 times 2, which is 810 kWh, costing 810 times 0.1819, which is 147.34. The arithmetic is simple, but it is worth doing explicitly, because the cost of a second unit is the cost that surprises people: it is not a small addition to the first, it is the first cost again.
A second season is a different question from a second unit. The scenario above assumed a season of about 90 days, and a season is not a fixed length: a cool summer is shorter, a hot summer is longer, and the hours per day rise with the heat. The way to handle that is to run the calculator three times, with a short season, a typical season and a long one, and to keep all three answers. The three answers are a range, and a range is more honest than a single figure for a season you cannot predict. The monthly figure, compared with a real bill, is the anchor for the range: if the monthly figure matches a real month, the seasonal range is built on something solid.
Finally, remember what the calculator leaves out, because the assumptions section on the calculator page lists it. Installation, maintenance and the cost of the unit itself are not in the running cost, and neither is the electricity used by the fan when the compressor is off. The running cost is the cost of the cooling, and it is the number to budget for, but it is not the whole cost of owning the unit, and a decision to buy one should count both.
Try it with your own numbers
Sources
- Rating definitions: EER as BTU/h per watt at standard conditions (AHRI / U.S. DOE appliance standards documentation).
- Prices in the example: EIA residential average 2026 YTD; Ofgem price cap October–December 2026.